Hydrastore power unit

Field Bus Communication receivers, part of our Hetronic Radio Control range

RX ES  product image

RX ES

Hetronic logo
  • Weight: 0.74kg (1.6 lbs)
  • IP65 case
  • Antenna: external via TNC connector
  • Can operate at a wide range of frequencies
  • Range: 100m (300')

Enclosed in a rugged and impact resistant HS-1 enclosure, the RX ES receiver was designed to work with applications that require bus communication, namely, ProfiNet, Profibus RS485/232, Modbus, DeviceNet or Ethernet. All bus receiver options offer analog/digital inputs and outputs that are fully programmable to meet customer requirements. RX ES receiver offers two (2) monitored safety rated Main Contact relays, user friendly interfacing and quick connect/disconnect options depending on receiver hardware configuration. Typical operating voltage range is 12VDC – 24VDC.

View PDF brochure

RX ES-CAN-HL  product image

RX ES-CAN-HL

Hetronic logo
  • Weight: 1.9kg (4.0 lbs)
  • IP65 case
  • Can operate at a wide range of frequencies
  • Range: 100m (300') LINE OF SIGHT

The RX ES-CAN-HL receiver is enclosed in a rugged and impact resistant HS-1 enclosure. It is software configurable, offering a selection of CAN bus communication protocols such as CANopen, CANOpen Safety, SAE J1939, Parker IQAN and Generic CAN on two independent CAN buses. Apart from the analog/digital inputs and outputs, LED Feedback, and other settings configurable through software, the RX ES-CAN-HL provides the following onboard features: two (2) monitored safety rated Main Contact relays, two (2) independent CAN interfaces running different protocols simultaneously, two (2) radio frequency ports, two (2) switching relay digital outputs, four (4) digital outputs, four (4) analog inputs and RS232 control cable interface. Six (6) additional programmable digital I/O’s can be added using an optional I/O expansion module. The receiver comes with either a quick connect/disconnect 30 pol. connection or with cable gland entry and easy access to the onboard connectors. Typical operating voltage range is 12VDC – 24VDC.

View PDF brochure

RX ES-PROFINET  product image

RX ES-PROFINET

Hetronic logo
  • Weight: 1.9kg (4.0 lbs)
  • IP65 case
  • Can operate at a wide range of frequencies
  • Range: 100m (300')

RX ES-PROFINET-HL field bus receiver is enclosed in a rugged and impact resistant HS-1 enclosure, is fully programmable and can be easily configured and connected through an RJ45 port to a vast range of industrial equipment that require fast data exchange using Profinet communication protocol. RX ES-PROFINET-HL also offers two (2) monitored safety rated Main Contact relays, two (2) switching relay digital outputs and optional RS232 control cable interface. It comes with quick connect/disconnect connectors and provides LED diagnostics for power/operation, transmission signal reception and main contact error. Typical operating voltage range is 12VDC – 24VDC.

View PDF brochure

RX ES-MODBUS TCP  product image

RX ES-MODBUS TCP

Hetronic logo
  • Weight: 0.91kg (1.6 lbs)
  • IP65 case
  • Frequencies: 4xxMHz, 8xxMHz, 9xxMHz, 2.4GHz
  • Range: 100m

Enclosed in a rugged and impact resistant HS-1 enclosure, the fully programmable and configurable RX ES-MODBUS TCP field bus receiver was designed to interface with a wide range of industrial applications that require fast data exchange using Modbus TCP protocol. It also offers two (2) monitored safety rated Main Contact relays, two (2) switching relay digital outputs and optional RS232 control cable interface. RX ES-MODBUS TCP provides RJ45 port, quick connect/disconnect connectors and LED diagnostics for power/operation, transmission signal reception and main contact error. Typical operating voltage range is 12VDC – 24VDC.

View PDF brochure

RX ES-ETHERNET IP  product image

RX ES-ETHERNET IP

Hetronic logo
  • Weight: 0.91 (1.6 lbs)
  • IP65 case
  • Antenna: external via TNC connector
  • Can operate at a wide range of frequencies
  • Range: 100m (300')

RX ES-ETHERNET IP field bus receiver is enclosed in a rugged and impact resistant HS-1 enclosure, is fully programmable and can be easily configured and connected through an RJ45 port to a vast range of industrial equipment that require fast data exchange using EtherNET IP protocol. RX ES-ETHERNET IP also offers two (2) monitored safety rated Main Contact relays, two (2) switching relay digital outputs and optional RS232 control cable interface. It comes with quick connect/disconnect connectors and provides LED diagnostics for power/operation, transmission signal reception and main contact error. Typical operating voltage range is 12VDC – 24VDC.

View PDF brochure

RX ES-ETHERCAT  product image

RX ES-ETHERCAT

Hetronic logo
  • Weight: 0.74kg (1.6 lbs)
  • IP65 case
  • Antenna: external via TNC connector
  • Can operate at a wide range of frequencies
  • Range: 100m (300')

Enclosed in a rugged and impact resistant HS-1 enclosure, the fully programmable and configurable RX ES-ETHERCAT field bus receiver was designed to interface with a wide range of industrial applications that require fast data exchange using EtherCAT protocol. It also offers two (2) monitored safety rated Main Contact relays, two (2) switching relay digital outputs and optional RS232 control cable interface. RX ES-ETHERCAT provides RJ45 port, quick connect/disconnect connectors and LED diagnostics for power/operation, transmission signal reception and main contact error. Typical operating voltage range is 12VDC – 24VDC.

View PDF brochure