Type / Mounting/ Format Part Number Description Pressure (bar) Max Flow (lpm) Size Datasheet
Cetop subplate mounted DLHZO-TES /K Directionals with on-off signals. Direct, sleeve execution, zero overlap, on-board driver, LVDT transducer, fieldbus, smart tuning 350 70 06 FY200
Cetop subplate mounted DLKZOR-TES /K Directionals with on-off signals. Direct, sleeve execution, zero overlap, on-board driver, LVDT transducer, fieldbus, smart tuning 350 130 10 FY200
Cetop subplate mounted DHZO-TES /K Directionals with on-off signals. Direct, positive or zero overlap, on-board driver, LVDT transducer, fieldbus, smart tuning 350 80 06 FY200
Cetop subplate mounted DKZOR-TES /K Directionals with on-off signals. Direct, positive or zero overlap, on-board driver, LVDT transducer, fieldbus, smart tuning 350 180 10 FY200
Cetop subplate mounted DPZO-LES /K Directionals with on-off signals. Piloted, positive or zero overlap, on-board driver, 2 LVDT transducers, fieldbus 350 180-3500 10-35 FY200
Cetop subplate mounted DPZO-TES /K Directionals with on-off signals. Piloted, positive or zero overlap, on-board driver, 2 LVDT transducers, fieldbus 350 180-3500 10-35 FY200
Cetop subplate mounted DLHZO-TES /U Directionals with double power supply. Direct, sleeve execution, zero overlap, on-board driver, LVDT transducer, fieldbus, smart tuning 350 70 06 FY100
Cetop subplate mounted DLKZOR-TES /U Directionals with double power supply. Direct, sleeve execution, zero overlap, on-board driver, LVDT transducer, fieldbus, smart tuning 350 130 10 FY100
Cetop subplate mounted DHZO-TES /U Directionals with double power supply. Direct, positive or zero overlap, on-board driver, LVDT transducer, fieldbus, smart tuning 350 80 06 FY100
Cetop subplate mounted DKZOR-TES /U Directionals with double power supply. Direct, positive or zero overlap, on-board driver, LVDT transducer, fieldbus, smart tuning 350 180 10 FY100
Cetop subplate mounted DPZO-LES /U Directionals with double power supply. Piloted, positive or zero overlap, on-board driver, 2 LVDT transducers, fieldbus 350 180-3500 10-35 FY100
Cetop subplate mounted DPZO-TES /U Directionals with double power supply. Piloted, positive or zero overlap, on-board driver, 2 LVDT transducers, fieldbus 350 180-3500 10-35 FY100