Explosion Proof illustration 1Explosion Proof illustration 2Explosion Proof illustration 3Explosion Proof illustration 4
TypeHeading / type / mounting / formatPart numberDescriptionPressure (bar)Flow (lpm)SizeAtos catalogue page
DirectionalCetop subplate mountedDHZA-AProportional directional, without transducer, direct acting, positive overlap, multi certification350606FX100 External link
DirectionalCetop subplate mountedDKZA-AProportional directional, without transducer, direct acting, positive overlap, multi certification31512010FX100 External link
DirectionalCetop subplate mountedDHZA-AESProportional directional, without transducer, direct acting, positive overlap, On board drivers, Optional fieldbus, multi-certification350606FX110 External link
DirectionalCetop subplate mountedDKZA-AESProportional directional, without transducer, direct acting, positive overlap, On board drivers, Optional fieldbus, multi-certification31512010FX110 External link
DirectionalCetop subplate mountedDPZA-AProportional directional, without transducer, pilot operated, positive overlap, multi certification350180-150010FX200 External link
DirectionalCetop subplate mountedDPZA-AESProportional directional, without transducer, pilot operated, positive overlap, On board drivers, Optional fieldbus, multi certification350180-150010FX210 External link
Explosion Proof illustration 1Explosion Proof illustration 2Explosion Proof illustration 3Explosion Proof illustration 4
TypeHeading / type / mounting / formatPart numberDescriptionPressure (bar)Flow (lpm)SizeAtos catalogue page
DirectionalCetop subplate mountedDPZA-TProportional directional, with LVDT transducer, pilot operated, positive overlap, On board drivers, Optional fieldbus, multi certification350180-100010FX220 External link
DirectionalCetop subplate mountedDHZA-TProportional directional, with LVDT transducer, direct acting, positive overlap, multi certification350606FX120 External link
DirectionalCetop subplate mountedDKZA-TProportional directional, with LVDT transducer, direct acting, positive overlap, multi certification31515010FX120 External link
DirectionalCetop subplate mountedDHZA-TESProportional directional, with LVDT transducer, direct acting, positive overlap, On board drivers, Optional fieldbus & P/Q control, multi certification350606FX130 External link
DirectionalCetop subplate mountedDKZA-TESProportional directional, with LVDT transducer, direct acting, positive overlap, On board drivers, Optional fieldbus & P/Q control, multi certification31515010FX130 External link
DirectionalCetop subplate mountedDPZA-LESProportional directional, with 2 x LVDT transducer, pilot operated, positive overlap, On board drivers, Optional fieldbus & P/Q control, multi certification350180-80010FX230 External link
Explosion Proof illustration 1Explosion Proof illustration 2Explosion Proof illustration 3Explosion Proof illustration 4
TypeHeading / type / mounting / formatPart numberDescriptionPressure (bar)Flow (lpm)SizeAtos catalogue page
DirectionalCetop subplate mountedDPZA-TProportional directional, with LVDT transducer, pilot operated, positive overlap, On board drivers, Optional fieldbus, multi certification350180-100010FX220 External link
DirectionalCetop subplate mountedDHZA-TProportional directional, with LVDT transducer, direct acting, positive overlap, multi certification350606FX120 External link
DirectionalCetop subplate mountedDKZA-TProportional directional, with LVDT transducer, direct acting, positive overlap, multi certification31515010FX120 External link
DirectionalCetop subplate mountedDHZA-TESProportional directional, with LVDT transducer, direct acting, positive overlap, On board drivers, Optional fieldbus & P/Q control, multi certification350606FX130 External link
DirectionalCetop subplate mountedDKZA-TESProportional directional, with LVDT transducer, direct acting, positive overlap, On board drivers, Optional fieldbus & P/Q control, multi certification31515010FX130 External link
DirectionalCetop subplate mountedDPZA-LESProportional directional, with 2 x LVDT transducer, pilot operated, positive overlap, On board drivers, Optional fieldbus & P/Q control, multi certification350180-80010FX230 External link
Explosion Proof illustration 1Explosion Proof illustration 2Explosion Proof illustration 3Explosion Proof illustration 4
TypeHeading / type / mounting / formatPart numberDescriptionPressure (bar)Flow (lpm)SizeAtos catalogue page
DirectionalCetop subplate mountedDHADirectional spool valve, direct acting, multi certification350706EX010 External link
DirectionalCetop subplate mountedDHWIntrinsically safe directional spool valve, direct acting, multi certification350256EX100 External link
DirectionalCetop subplate mountedDPHADirectional spool valve, pilot operated, multi certification350160-100010EX030 External link
DirectionalCetop subplate mountedDPHWIntrinisically safe directional spool valve, pilot operated, multi certification350160-70010EX130 External link
DirectionalCetop subplate mounted003290 DHADirectional spool valve with internal suppression diode, direct acting, multi certification350506TE140 External link
Explosion Proof illustration 1Explosion Proof illustration 2Explosion Proof illustration 3
TypeHeading / type / mounting / formatPart numberDescriptionPressure (bar)Flow (lpm)SizeAtos catalogue page
DirectionalCetop subplate mounted003290 DLAHDirectional poppet valve with internal suppression diode, direct acting, multi certification350126TE140 External link
DirectionalCetop subplate mounted003290 DLAHMDirectional poppet valve with internal suppression diode, direct acting, multi certification250306TE140 External link
DirectionalCetop subplate mountedDLAHDirectional poppet valve, direct acting, multi certification350126EX020 External link
DirectionalCetop subplate mountedDLAHMDirectional poppet valve, direct acting, multi certification250306EX020 External link
DirectionalCetop subplate mountedDLHPXDirectional poppet valve, hydraulically operated, stainless, multi certification315406E135 External link
DirectionalCetop subplate mountedDLWHIntrinsically safe directional poppet valve, direct acting, leak free, optional 2w2p / 3w2p, multi certification350126EX120 External link
Explosion Proof illustration 1Explosion Proof illustration 2
TypeHeading / type / mounting / formatPart numberDescriptionPressure (bar)Flow (lpm)SizeAtos catalogue page
DirectionalCartridgeLIQZA-LESProportional 2 way flow control with 2 x LVDT transducer, pilot operated, On board drivers, Optional fieldbus, multi certification4201200-16000100FX360 External link
DirectionalCartridgeLIQZA-LProportional 2 way flow control with 2 x LVDT transducer, pilot operated, multi certification4201200-16000100FX350 External link
DirectionalCartridgeLIQZA-LESServoproportional 3 way flow control with 2 x LVDT transducer, pilot operated, On board drivers, Optional fieldbus & P/Q function, multi certification420500-500010FX360 External link
DirectionalCartridgeLIQZA-LServoproportional 3 way flow control with 2 x LVDT transducer, pilot operated, multi certification420500-5001100FX350 External link
Explosion Proof illustration 1Explosion Proof illustration 2
TypeHeading / type / mounting / formatPart numberDescriptionPressure (bar)Flow (lpm)SizeAtos catalogue page
DirectionalCartridgeLIDEW-AODirectional poppet valve, pilot operated, multi certification350240-400016-63EX050 External link
DirectionalCartridgeLIDBH-AODirectional poppet valve, pilot operated with shuttle, multi certification350240-400016-63EX050 External link
DirectionalCartridgeLIDEW-WOIntrinsically safe directional poppet valve, pilot operated, multi certification350240-400016-63EX150 External link
DirectionalCartridgeLIDBH-WOIntrinsically safe directional poppet valve, pilot operated with shuttle, multi certification350240-400016-63EX150 External link

We operate a network of regional Atos distributors to fulfil your order fast

Find your nearest distributor

Can't find what you're looking for?

Call our knowledgeable team Mon–Fri 8:30am–5pm

Systems & Components Division 01427 874445
sales@hydrastore.co.uk